EN 1486: European Textile Standard for Firefighting
Flame Propagation
ISO 15025
(Method A)
Each liner
No hole
Flame persistence ≤ 2s
Residual incandescence ≤ 2s
Radiant Heat
EN ISO 6942
40kw/m²
The assembly
of components
RHTI24 ≥ 120s.
(Radiant Heat Transfer Index)
Time necessary to increase temperature by 24°
Convective Heat
EN 367
The assembly
of components
RHTI24 ≥ 21s.
(Radiant Heat Transfer Index)
Time necessary to increase temperature by 24°C
Contact Heat
EN 702
300°C
The assembly
of components
Threshold time ≥ 15s.
Time necessary to increase temperature by 10°C
Heat Resistance
ISO 17493
255 ± 10°C
Each liner
Must not melt,
drip or ignite or shrink more than 5%
Surface Wetting
EN 24920
at 20°C
External material
Spray Test ≥ 4
Tensile Strength
EN ISO 1421
Method 1
External aluminized materials
≥ 600N
EN ISO 13934-1
Inner liner
≥ 350N
Tear Strength
EN ISO 4674-1
Method B
External material
≥ 25N